Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Arq. bras. oftalmol ; 79(2): 73-77, Mar.-Apr. 2016. tab
Article in English | LILACS | ID: lil-782797

ABSTRACT

ABSTRACT Purpose: To compare visual acuity (VA), contrast sensitivity, stereopsis, and subjective visual performance of Acuvue® Oasys® for Presbyopia (AOP), Air Optix® Aqua Multifocal (AOMF), and Air Optix® Aqua Single Vision (AOSV) lenses in patients with presbyopia. Methods: A single-blinded crossover trial was conducted. Twenty patients with mild presbyopia (add ≤+1.25 D) and 22 with moderate/severe presbyopia (add ≥+1.50 D) who wore lenses bilaterally for 1 h, with a minimum overnight washout period between the use of each lens. Measurements included high- and low-contrast visual acuity (HCVA and LCVA, respectively) at a distance, contrast sensitivity (CS) at a distance, HCVA at intermediate (70 cm) and near (50 cm & 40 cm) distances, stereopsis, and subjective questionnaires regarding vision clarity, ghosting, overall vision satisfaction, and comfort. The test variables were compared among the lens types using repeated-measures ANOVA. Results: Distance variables (HCVA, LCVA, and CS) were significantly worse with multifocal lens than with AOSV lens (p≤0.008), except for AOMF lens in the mild presbyopia group in which no significant difference was observed (p>0.05). Multifocal lenses had significantly greater HCVA at 40 cm than AOSV lens (p≤0.026). AOMF lens had greater intermediate HCVA than AOP lens (p<0.03). AOP lens demonstrated greater improvements in stereopsis than AOMF and AOSV lens in the moderate/severe presbyopia group (p≤0.03). Few significant differences in subjective variables were observed, with no significant difference in the overall vision satisfaction observed between lens types (p>0.05). The proportions of patients willing to buy AOSV, AOMF, and AOP lenses were 20%, 40%, and 50%, respectively, in the mild presbyopia group and 14%, 32%, and 23%, respectively, in the moderate/severe presbyopia group; however, these differences were not statistically significant (p≥0.159). Conclusions: Further development of multifocal lenses is required before significant advantages of multifocal lenses over single vision lens are observed in patients with presbyopia.


RESUMO Objetivo: Comparar a acuidade visual, sensibilidade ao contraste, estereopsia e desempenho visual subjetivo de présbitas usando lentes de contato Acuvue Oasys para presbiopia (AOP), Air Optix Aqua Multifocal (AOMF) e Air Optix Aqua Single Vision (AOSV). Método: Foi realizado estudo mascarado simples, cruzado. Vinte pacientes com presbiopia baixa (adição ≤+1,25 D) e 22 com presbiopia média/alta (adição ≥+1,50 D) usaram cada lente bilateralmente durante 1 hora, com descanso mínimo de uma noite entre as diferentes lentes. As medições incluíram acuidade visual para distância em alto e baixo contraste (HCVA, LCVA), sensibilidade ao contraste para distância (CS), HCVA para distância intermediária (70 cm) e para perto (50 cm e 40 cm), estereopsia e questionários subjetivos sobre nitidez visual, fantasmas, satisfação visão geral e conforto. As variáveis foram comparadas entre os tipos de lentes, utilizando medidas repetidas ANOVA. Resultados: As variáveis para distância (HCVA, LCVA, CS) foram significativamente piores com as multifocais em relação a AOSV (p≤0,008), exceto para AOMF no grupo de baixa adição, que não foi significativamente diferente (p>0,05). As multifocais foram significativamente melhores do que a AOSV para HCVA em 40 cm (p≤0,026). AOMF superou AOP para HCVA intermediária (p<0,03). AOP superou AOMF e AOSV em relação à estereopsia no grupo de presbiopia médio/alto (p≤0,03). Houve poucas diferenças significativas nas variáveis subjetivas, mas a satisfação visual global não foi significativamente diferente entre as lentes (p>0,05). A disposição para comprar lentes AOSV, AOMF e AOP foi: 20%, 40%, 50%, respectivamente, no grupo de presbiopia baixa; 14%, 32%, 23% no grupo de presbiopia média/alto, mas essas diferenças não foram estatisticamente significativas (p≥0,159). Conclusões: Melhorias futuras parecem ser necessárias para produção de uma lente multifocal que forneça aos présbitas uma vantagem significativa sobre a lente de visão única.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Presbyopia/rehabilitation , Contact Lenses, Hydrophilic , Equipment Design , Presbyopia/classification , Vision Tests , Contrast Sensitivity/physiology , Visual Acuity/physiology , Single-Blind Method , Prospective Studies , Surveys and Questionnaires , Patient Satisfaction , Cross-Over Studies , Depth Perception/physiology
2.
Arq. bras. oftalmol ; 77(2): 76-80, Mar-Apr/2014. tab, graf
Article in English | LILACS | ID: lil-716253

ABSTRACT

Purpose: To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC) on visual performance. Methods: This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an artificial pupil contact lens in the nondominant eye and a CBMCLC. After a month of lens wear, the binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance, and near contrast sensitivity and near stereoacuity (NSA) were measured under photopic conditions (85 cd/m2). Moreover, BDVA and binocular distance contrast sensitivity were examined under mesopic conditions (5 cd/m2). Results: Visual acuity at an intermediate distance and near vision was better with the CBMCLC than with the artificial pupil (p<0.05). Statistically significant differences were found in contrast sensitivity between the two types of correction for distance (under mesopic conditions) and for near vision, with the CBMCLC exhibiting better results in both cases (p<0.05). The mean NSA values obtained for the artificial pupil contact lens were significantly worse than those for the CBMCLC (p=0.001). Conclusion: The CBMCLC provided greater visual performance in terms of intermediate and near vision compared with the artificial pupil contact lens. .


Objetivo: Avaliar e comparar os efeitos da pupila artificial baseada em lentes de contato e a combinação equilibrada de lente de contato multifocal contralateral (CBMCLC) sobre o desempenho visual. Métodos: Estudo realizado na Universidade de Valência, Espanha. Em um projeto de estudo do tipo "cross-over", 38 pacientes présbitas foram avaliados utilizando uma lente de contato com pupila artificial no olho não-dominante e CBMCLC. Após 1 mês, foram avaliadas, em condições fotópicas (85 cd/m2), a acuidade visual binocular para distância (BDVA), a acuidade visual binocular para perto (BNVA), a curva de desfocagem, a sensibilidade ao contraste binocular para distância e para perto, assim como a acuidade estereoscópica para perto (NSA). Além disso, a BDVA e a sensibilidade ao contraste binocular para distância foram avaliadas em condições mesópicas (5 cd/m2). Resultados: A acuidade visual em distâncias intermediárias e para perto foram melhores com CBMCLC do que com pupila artificial (p<0,05). Foram encontradas diferenças estatisticamente significativas entre a sensibilidade ao contraste com os dois tipos de correção para distância (em condições mesópicas) e para perto, com CBMCLC ser melhor em ambos os casos (p<0,05). Os valores médios da NSA obtidos com as lentes de contato das pupilas artificiais foram significativamente piores do que com CBMCLC (p=0,001). Conclusão: CBMCLC proporciona melhor desempenho visual para visão intermediária e para perto do que a lente de contato com pupila artificial. .


Subject(s)
Female , Humans , Male , Middle Aged , Contact Lenses, Hydrophilic , Pupil , Presbyopia/rehabilitation , Cross-Over Studies , Color Vision/physiology , Contrast Sensitivity/physiology , Equipment Design , Treatment Outcome , Visual Acuity/physiology
3.
Arq. bras. oftalmol ; 60(1): 95-8, fev. 1997. tab
Article in Portuguese | LILACS | ID: lil-193543

ABSTRACT

Adaptou-se lente de contato gelatinosa multifocal Occasions em 47 pacientes présbitas, 36 mulheres e 11 homens. A idade variou de 41 a 52 anos. 66 p/cento eram hipermétropes. O tempo de seguimento médio foi de 8,6 meses. 72,3 p/cento dos pacientes obtiveram acuidade visual para perto igual a J1. O índice de sucesso na adaptaçäo da lente foi de 55 por cento. Vinte e dois pacientes näo tinham experiência prévia no uso de lentes de contato näo foi significante. A queixa mais comum em 42,5 p/cento dos pacientes foi a de baixa da acuidade visual para longe, especialmente à noite. O estudo mostra a avaliaçäo clínica da lente Occasions para a correçäo óptica da presbiopia


Subject(s)
Humans , Male , Female , Middle Aged , Adult , Contact Lenses, Hydrophilic , Presbyopia/rehabilitation
SELECTION OF CITATIONS
SEARCH DETAIL